CN / EN

/
/
Measurement Services
1/1
Number of views:
1163

Measurement Services

■ 1、Wavefront Distortion Measurement Equipment Name:The Interferometer Wavelength Range:633nm, 1064nm Size Range:Φ3mm~10mm×20mm~150mm@1064nm; Φ3~100mm×250mm@633nm Measuring Accuracy:λ/12@1064nm;
Number of views:
1163
Quantity
-
+
1
product description

■ 1、Wavefront Distortion Measurement

Equipment Name:The Interferometer

Wavelength Range:633nm, 1064nm

Size Range:Φ3mm~10mm×20mm~150mm@1064nm;

Φ3~100mm×250mm@633nm

Measuring Accuracy:λ/12@1064nm;

λ/20@633nm

Range of application: It fits measure wavefront distortion of the material which can through the light of 633nm or 1064nm, for example Ho:Cr:Tm:YAG, Er:YAG, etc.

■ 2、Extinction Ratio Measurement

Equipment Name:The Extinction Ratio Equipment

Wavelength Range:633nm, 1064nm

Size Range:Φ3mm~10mm×250mm

Measuring Error:≤±5%

Range of application: It fits measure residual strain of the material which can through the light of 633nm or 1064nm, for example Ho:Cr:Tm:YAG, Er:YAG, etc.

■ 3、Angular Measurement

Equipment Name:The High-precision Goniometer

Measuring range: The diameter of the sample ≥Φ3mm

Measuring Accuracy: ≤0.3"

Range of application: Measuring the geometry angle of the plane with the certain reflection rate, as crystal prism, metal polyhedron, etc.

■ 4、Flatness Measurement

Equipment Name: The ZYGO Interferometer

Measuring range:Φ3mm~100mm

Measuring Accuracy:≤λ/20@633nm

Range of application: Measuring the flatness of the processed surface.

■ 5、Stress Measurement

Equipment Name:DIAS-1600 Measurement of Residual Stress

Measuring range:Φ5mm~60mm

Measuring Accuracy:±6nm

Range of application: Testing micro stress and stress distribution of the sample

■ 6、Spectrum Measurement:

Equipment Name:LAMBDA950 spectrophotometer

Measuring range:

Wavelength Range:185nm~3300nm,

Size Range:Φ3mm~20mm×40mm@transmission Φ5mm~20mm×90mm@reflection

Measuring Accuracy:±0.1nm

Range of application:

Testing the transmission with 0-60 degree;

Testing the reflection with 6-68 degree;

Testing the diffuse reflection of the ceramics;

Testing the transmission and the reflection with P or S polarized light。

■ 7、The LASER Damage Threshold Test

Equipment Name:The LASER Damage Threshold Test System

Measuring range:

Wavelength:1064nm,

The time of impulse:10ns,

Power density:600MW/cm2 ~ 2000 MW/cm2

Power Fluctuates:≤±5%

Range of application: The system is applied to test the damage resistance of the coating, laser crystal, ceramics and glass.

■ 8、The Single Pass Loss System

Equipment Name:The Single Pass Loss System

Measuring range:

Wavelength:1064nm

Size Range:Φ4mm~20mm×250mm

Measuring error:≤±10%

Range of application: The system is applied to test the single pass light energy loss when 1064nm laser past through the material.

■ 9、Low Absorptiometer

Equipment Name:PTI Low Absorptiometer

Measuring range:

Wavelength:1064nm

Measuring Accuracy:

Less than 1ppm

Range of application: The system is applied to test the low absorption of the coating, laser crystal and glass.

■ 10、FT-IR Spectrometer

Equipment Name:Frontier Optica FT-IR Spectrometer

Measuring range:

Wavelength Range:7800-350cm-1

Measuring Accuracy:

Less than 0.01cm-1

Range of application:

Testing the transmission of the IR coating and IR material

Keyword:
0px
div
p_gridbox
width
p_gridcell
margin-left
margin-right
none
auto
We could not find any corresponding parameters, please add them to the properties table