1. Name: Automatic High-Precision Optical Thin Film Coating Machine
2. Quantity: 1 set
3. Equipment Composition:
The automatic high-precision optical thin film coating machine includes a vacuum chamber, vacuum exhaust control system, heating control system, vacuum measurement and pressure control system, substrate rotation system, evaporation source system, ion source assisted evaporation system, film thickness monitoring system, coating control system, vacuum control system and auxiliary systems.
4. Main Technical Specifications
4.1 Vacuum Chamber
4.1.1 Basic Requirements
1) Vacuum Chamber Shape: Front-opening box structure
2) Vacuum Chamber Dimensions: Diameter 1300mm, Height 1610mm
3) Vacuum Chamber Material: Stainless steel SUS304
4) Vacuum Chamber Cooling Method: Stainless steel pipe water cooling
4.1.2 Main Interfaces
1) 1 substrate observation window (equipped with purple-black strong light-proof glass)
2) 2 evaporation source observation windows (equipped with purple-black strong light-proof glass)
3) 1 reflective optical monitoring system interface (installed on the top of the vacuum chamber)
4) 1 ion source interface
5) 1 ion source neutralizer interface
6) 2 electron gun crucible interfaces
7) 1 pressure reducing valve interface
4.1.3 Baffle Interfaces
1) 2 electron gun baffle interfaces (installed at the bottom of the vacuum chamber)
2) 1 ion source baffle interface (installed at the bottom of the vacuum chamber)
3) 2 film thickness correction plate interfaces (installed on both sides of the vacuum chamber)
4.1.4 Gauge Interfaces
1) 1 gauge interface for measuring the vacuum of the measuring pipe
2) 1 gauge interface for measuring the high vacuum of the vacuum chamber
3) 1 gauge interface for measuring the rough vacuum of the vacuum chamber
4.1.5 Spare Interfaces
1) 2 Φ70 ICF interfaces
2) 4 KF40 interfaces
3) 1 KF25 interface
4) 1 transmissive optical thickness monitoring system flange (at the bottom of the vacuum chamber)
5) 1 Φ200mm flange
4.2 Vacuum Exhaust Control System
4.2.1 Basic Requirements
1) Rough vacuum: From atmospheric pressure to 50Pa, within 8min
2) Ultimate vacuum: Below 7.0E-5Pa
3) Vacuum recovery: Reach 1.3E-3Pa within 15min
4) Leak rate: Below 9.0E-5Pa・m3/s
4.2.2 Exhaust System Composition
1) Low vacuum exhaust system requires 1 dry pump and 1 Roots pump.
2) The high vacuum exhaust system requires an oil-free vacuum system, including 2 cryopumps, 2 cryopump compressors, 2 cold trap mechanisms, 2 cold trap mechanism compressors, 1 cold trap mechanism automatic temperature control system, and 1 cryopump automatic regeneration system.
3) Valves required include 2 high vacuum valves, 2 auxiliary valves, 1 low vacuum valve, 1 slow low vacuum valve, 1 inflation valve, 1 slow inflation valve, and 3 nitrogen inflation valves used during cryopump regeneration.
4.3 Heating Control System
4.3.1 Basic Requirements
1) Maximum set temperature: 350℃
2) Reach 300℃ after heating for 40min
3) Temperature uniformity: 300±10℃ (after heating for 40min)
4.3.2 Substrate Heating Mechanism
The substrate heating mechanism requires PID control, using nichrome heating wires, with an output power of 21kW. It needs 3 workpiece tray heating sealing flanges with water-cooled inlet and outlet connectors, 1 K-type thermocouple, and 1 temperature indicator controller.
4.3.3 Vacuum Chamber Side Heating Mechanism
The vacuum chamber side heating mechanism requires PID control, using nichrome heating wires, with an output power of 9kW and a maximum heating temperature of 150℃. It needs to be equipped with 1 K-type thermocouple and 1 temperature indicator controller.
4.4 Vacuum Measurement and Pressure Control System
4.4.1 Compound Vacuum Gauge
The compound vacuum gauge is required to consist of:
1) 2 vacuum gauges
2) 1 Pirani gauge for measuring the vacuum of the measuring pipe
3) 2 Pirani gauges for testing the vacuum of the cryopumps
4) One B-A/Pirani composite gauge tube for measuring the rough vacuum of the measurement vacuum chamber
5) One Penning vacuum gauge for gas import control and measurement of the high vacuum of the measurement vacuum chamber
4.4.2 Automatic Pressure Control System (APC)
The Automatic Pressure Control System (APC) requires an operating pressure range of 6.6E-2Pa~3.0 E-3Pa and needs to be equipped with one gas import valve and one gas flow meter
4.5 Substrate Rotation System
4.5.1 Substrate Rotation Mechanism
The substrate rotation mechanism requires an integrated optical monitoring and crystal control system, driven from the center, planetary type, with a speed adjustment range of 10~50rpm
4.5.2 Planetary Disk
Planetary disk material: Stainless steel
4.6 Evaporation Source System
4.6.1 Electron Gun/Power Supply
1) The electron gun requires two electron gun heads (10kW, 270° deflection, filament Φ0.55mm), one power supply, two external controllers, one dual electron gun simultaneous use controller, one automatic arc extinguishing recovery system, and two terminals
2) Main performance: The voltage is continuously adjustable, operating range: 4~-10kV; The current is continuously adjustable even at a working voltage of -10kV, operating range: 0~1.0A
4.6.2 Water-cooled annular copper crucible stage
1) Dimensions: φ302 (outer diameter) ×φ228 (inner diameter) ×H15mm (height)
2) Drive method: Specified speed rotation, speed range 5~120 min/revolution
3) Control method: Rotation mode and FIX mode
4.6.3 Water-cooled 24-point copper crucible stage
1) Crucible dimensions: Outer diameter φ40×H17mm (outer height)
2) Control method: Positioning encoder
4.6.4 Electron gun baffle
Dimensions: φ260mm±5mm
4.7 Ion Source Assisted Evaporation System
4.7.1 Radio Frequency Ion Source
1) Grid size: 17cm
2) Maximum RF power: 1000W@13.56MHz
3) Beam voltage: 100V~1500V
4) Maximum beam current: 1200mA
5) Ion current density distribution: Within ±10%
6) Acceleration voltage: 100V~1000V
7) Standard gas import volume: Oxygen 50sccm or Argon 30sccm
4.7.2 Radio Frequency Neutralizer
1) Maximum RF power: 150W@13.56MHz
2) Maximum neutralization current: 2400mA
3) Standard gas import volume: Argon 8sccm
4.7.3 Power Supply
The power supply requires one controller, one DC generator, and one neutralizer DC generator
4.7.4 Radio Frequency Power Supply
The radio frequency power supply requires one radio frequency power supply, one radio frequency matcher, one neutralizer radio frequency power supply, and one neutralizer radio frequency matcher (manual type)
4.7.5 3-way gas import system
The 3-way gas import system requires the following:
1) One flow controller
2) One oxygen import mechanism for the ion source, with a maximum operating flow rate of 100sccm
3) One argon import mechanism for the ion source, with a maximum operating flow rate of 50sccm
4) One argon import mechanism for the neutralizer, with a maximum operating flow rate of 20sccm
4.7.6 Ion source baffle
Dimensions: φ290mm±5mm
4.8 Film Thickness Monitoring System
*4.8.1 Optical Film Thickness Monitoring
The optical film thickness monitoring requires a reflective film thickness meter, a 60-point monitoring wafer rotation mechanism, and a monitoring wafer heating control mechanism to achieve automatic optical film thickness control during deposition
4.8.1.1 Reflective Film Thickness Meter
1) Wavelength range: 350~1100nm
2) Wavelength accuracy <±1nm
3) Wavelength resolution: Standard 6.5nm±1.0nm, at 546.1nm
4) Wavelength repeatability: ±0.25nm
5) Stability <±0.1%/h (60 min after lighting, stable ambient temperature, wavelength 500nm)
6) The reflective film thickness meter requires one reflective fiber optic system, one illuminator, one illuminator power supply, one spectrometer, one data processor, and one spectroscopic determination program
4.8.1.2 60-point monitoring wafer rotation mechanism
The 60-point monitoring wafer rotation mechanism is required to load and fix the monitoring wafers and accurately rotate the monitoring wafers to the next monitoring position
4.8.1.3 Monitoring Film Heating Control Mechanism
The monitoring film heating control mechanism requires PID control, using nichrome heating wire, with an output power of 0.24kW and a maximum heating temperature of 300℃. It needs to be equipped with one K-type thermocouple and one temperature indicator controller.
4.8.2 Crystal Film Thickness Monitoring
Crystal film thickness monitoring requires one control instrument and one 6-piece rotary crystal film thickness sensor to control the film deposition speed and physical thickness of the crystal oscillator, enabling automatic film deposition control.
4.9 Coating Control System
The coating control system requires an automatic coating software, computer, LCD monitor, and a UPS system shared by the PC and PLC; the automatic coating software requires functions including material melting, coating, thin film design data input, and process data recording; the thin film design data input function can read Runsheet data from Essential Macleod film system design software.
4.10 Vacuum Control System
The vacuum control system requires an electrical control cabinet, touch screen, program system, and remote controller; the program system requires functions including switching system, exhaust operation, coating operation, trigger switch, timing setting, and alarm indication; the remote controller requires functions including workpiece frame rotation, baffle, film thickness correction baffle, and crucible rotation.
4.11 Auxiliary System
4.11.1 Film Thickness Correction Baffle Mechanism
The film thickness correction baffle mechanism is required to be located directly below the planar planetary disk.
4.11.2 Stainless Steel Anti-fouling Plate
The stainless steel anti-fouling plate should be easy to install and remove.
4.11.3 Cooling Water System
The cooling water system requires supply and drainage pipelines, solenoid valves and manual control valves, and water flow switches.
4.11.4 Compressed Air System
The compressed air system requires regulating valves, filters, pressure gauges, and pipelines.
4.11.5 Power Voltage Stabilization System
The power voltage stabilization system requires a voltage regulator cabinet and electrical wiring.
4.12 Safety Protection and Spare Parts
*4.12.1 Safety Protection Circuit and Interlock Protection
1) When the compressed air pressure is below 0.35Mpa for a certain period of time, all valves in the exhaust system will automatically close, and an alarm will be triggered.
2) When the cooling water flow rate is below the normal value for a certain period of time, the cooling water flow related systems will automatically shut down, and an alarm will be triggered.
3) In case of power failure or power outage, all valves except the main cooling water valve must automatically close, and there is no automatic recovery function when the power is restored; to ensure safety, the inflation valve will automatically open 5 minutes after the power failure, the vacuum chamber will automatically inflate, and after stopping for 10 minutes, nitrogen will be automatically filled into the CP; when the temperature of the CP is maintained above 20K continuously for 30 minutes, the exhaust system must automatically regenerate.
4) It has a leakage protection function.
5) When the high vacuum valve is opened, the electron gun and ionization vacuum gauge can operate normally.
6) When the equipment malfunctions, the alarm light and alarm buzzer will start simultaneously, and the cause of the malfunction will be displayed on the touch control screen.
7) Emergency buttons are available on the main control cabinet front panel, next to the electron gun control cabinet, and next to the exhaust system.
4.12.2 Accessories
1) One set of operation instructions
2) One set of standard tools
3) One footrest
4) One set of standard maintenance tools for the ion source
4.12.3 Spare Parts
1) One set of anti-fouling plates
2) Two electron gun baffles
3) One ion gun baffle
4) 24 copper crucibles
This project has failed two public bidding processes, and it is planned to use single-source procurement this time;
The planned supplier for this project is Guangzhou Fafa Vacuum Technology Co., Ltd., Address: Room 201, Building 4, No. 7, Guangcong Sixth Road, Zhongluotan Town, Baiyun District, Guangzhou City, Unified Social Credit Code: 91440101MA5AUA655E, Legal Representative: Liu Lanhua;
Public announcement period of this project is 2022.06.08, 12:00-2022.06.13, 12:00 。
If you have any questions during the public announcement period, please contact: Name: Liu Hao, Tel: 15810945149, Contact Address: Inside the China Electronics Technology Group Corporation No. 11 Institute, No. 2 Courtyard, Jiuxianqiao Road, Chaoyang District, Beijing.
This is hereby announced
June 8, 2022
Guangzhou Fafa Vacuum Technology Co., Ltd. 91440101MA5AUA655E
Previous Page
Related Information
2024-05-22
View DetailsLASER World of PHOTONICS CHINA, the 18th Munich Shanghai Optoelectronics Exhibition
Beijing Leishengqiang will participate in the 18th Munich Shanghai Optical Fair from March 20-22, 2024. Booth No.: W2.2367. Welcome new and old customers to visit.
2024-03-11
View DetailsThe 25th China International Optoelectronic Exposition (CIOE)
As a large-scale and influential comprehensive exhibition of the optoelectronic industry, the 25th China International Optoelectronic Exposition will be held in Shenzhen. Beijing Leisheng Qiangshi will bring its latest and best products to the exhibition. New and old customers are welcome to visit and purchase products in one stop.
2024-03-11
View Details